Cat.6 UTP Outdoor Gel Filled Direct Burial Cable
UTP, 4-pair with rip cord
Polyolefin Jacket, UV Resistant
Gel filled (Non Conductive)
Supports all applications designed to operate over category 6 or lower rated systems.
Number of Pairs |
4 |
Color Code: Pair 1: Blue-White/Blue Pair 2: Orange-White/Orange Pair 3: Green-White/Green Pair 4: Brown-White/Brown Packaging:305m reel in box |
Conductor |
Solid Copper Ø 0.56 mm |
|
Insulation |
HDPE |
|
Separator: |
cross filler |
|
screen |
PET tape |
|
rip cord (optical) |
yes |
|
Water Proof |
Gel filled |
|
Outer sheath |
uv resistant Linear low-density polyethylene |
|
thickness of outer sheath |
0.55 mm |
|
cable outer diameter |
6.3 mm |
|
Colour |
balck |
Length: Cable weight: Wire size: Overall outside diameter: |
1000 ft/305 m 14~15 kg 23 AWG (Ø 0.56 mm) 6.3 mm |
ANSI/TIA Category Characteristic Impedance (Frequency: 1-200 MHz) DC Resistance Unbalance, maximum DC Resistance , maximum at 20˚C Propagation delay at100 MHz (ns/100m) Delay Skew Mutual Capacitance Nominal Velocity of Propagation (NVP) Coupling attenuation at 30˚C Operating Frequency, maximum |
6 100 ± 15 ohms 5 % 9.38 ohms/100 m <536 ≤35 ns 5.6 nF/100 m @ 1 kHz 69% 45MHz(dB) 250 MHz |
Frequency |
Attenuation |
NEXT (Min) |
PS NEXT (Min) |
ELFEXT (Min) |
PS ELFEXT (Min) |
Attenuation (Max) |
TCL (Min) |
PS ANEXT (Min) |
PS AACR-F (Min) |
RL (Min) |
MHz |
dB/100m |
dB |
dB |
dB/100m |
dB/100m |
dB |
dB |
dB |
dB |
dB |
4 |
4.2 |
66.3 |
63.3 |
56 |
53 |
3.8 |
44 |
67 |
66.2 |
23 |
8 |
5.9 |
61.8 |
58.8 |
49.9 |
46.9 |
5.3 |
41 |
67 |
60.1 |
24.5 |
10 |
6.6 |
60.3 |
57.3 |
48 |
45 |
5.9 |
40 |
67 |
58.2 |
25 |
16 |
8.3 |
57.2 |
54.2 |
43.9 |
40.9 |
7.5 |
38 |
67 |
54.1 |
25 |
20 |
9.3 |
55.8 |
52.8 |
42 |
39 |
8.4 |
37 |
67 |
52.2 |
25 |
25 |
10.5 |
54.3 |
51.3 |
40 |
37 |
9.4 |
36 |
67 |
50.2 |
24.3 |
31.25 |
11.7 |
52.9 |
49.9 |
38.1 |
35.1 |
10.5 |
35.1 |
67 |
48.3 |
23.6 |
62.5 |
16.9 |
48.4 |
45.4 |
32.1 |
29.1 |
15 |
32 |
65.6 |
42.3 |
21.5 |
100 |
21.7 |
45.3 |
42.3 |
28 |
25 |
19.1 |
30 |
62.5 |
38.2 |
20.1 |
200 |
31.7 |
40.8 |
37.8 |
22 |
19 |
27.6 |
27 |
58 |
32.2 |
18 |
250 |
35.9 |
39.3 |
36.3 |
20 |
17 |
31.1 |
26 |
56.5 |
30.2 |
17.3 |
300 |
39.8 |
38.1 |
35.1 |
18.5 |
15.5 |
34.3 |
/ |
55.3 |
28.7 |
17.3 |
400 |
46.9 |
36.3 |
33.3 |
16 |
13 |
40.1 |
/ |
53.5 |
26.2 |
17.3 |
500 |
53.4 |
34.8 |
31.8 |
14 |
11 |
45.3 |
/ |
52 |
24.2 |
17.3 |
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20˚C.
|
|
|
1. copper rod |
2. wire drawing |
3. Annealing |
|
|
|
4. Core insulation |
5. Wire twisting |
6. wire backing twisting |
|
|
|
7. Cabling |
8. Jacking |
9. Packing |