Copper Conductors XLPE Insulated Power Cable

500 m
MOQ
On Request
Price
Copper Conductors XLPE Insulated Power Cable
Features Gallery Product Description Request A Quote
Features
Specifications
Rated Voltage: 0.6 / 1kV
Conductor: Bare Copper
No. Of Cores: 4 Cores
Insulation: XLPE Compound
Armoured Type: Unarmoured
Sheath: PVC Compound
Highlight:

xlpe copper cable

,

xlpe pvc cable

,

4 core IEC 60502-1 Cable

Basic Infomation
Place of Origin: Shenzhen City, Mainland China
Brand Name: Shenzhen CTT cable
Certification: CE, CB
Model Number: YJV
Payment & Shipping Terms
Packaging Details: Steel wooden Drum
Delivery Time: 15 working days after payments
Payment Terms: L/C, T/T
Product Description

  IEC 60502-1 Cables

 

600/1000V, XLPE Insulated Cables according to IEC 60502-1

 

Applications

 

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

Construction

1. Conductors

------------------------------------------------------------------------------------------------------

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

------------------------------------------------------------------------------------------------------

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

------------------------------------------------------------------------------------------------------

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

 

 

  Physical and Electrical Characteristics:

 

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 0.7 1.8 13.0 283 38 50 4.61
4×6 0.7 1.8 14.2 376 49 62 3.08
4×10 0.7 1.8 16.7 567 67 84 1.83
4×16 0.7 1.8 19.1 829 88 109 1.15
4×25 0.9 1.8 23.2 1249 119 142 0.73
4×35 0.9 1.8 25.2 1689 146 170 0.52
4×50 1.0 1.9 25.5 2146 173 201 0.39
4×70 1.1 2.0 28.9 2944 218 245 0.27
4×95 1.1 2.1 32.5 3903 271 294 0.19
4×120 1.2 2.3 35.9 4967 315 333 0.15
4×150 1.4 2.4 40.2 6133 366 374 0.12
4×185 1.6 2.6 44.4 7600 422 421 0.10
4×240 1.7 2.8 49.4 9743 508 489 0.08
4×300 1.8 3.0 56.0 12271 592 555 0.06

 

 

INSTALLATION METHOD DETAILS

 

Copper Conductors XLPE Insulated Power Cable 0   Copper Conductors XLPE Insulated Power Cable 1   Copper Conductors XLPE Insulated Power Cable 2   Copper Conductors XLPE Insulated Power Cable 3
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
Copper Conductors XLPE Insulated Power Cable 4   Copper Conductors XLPE Insulated Power Cable 5   Copper Conductors XLPE Insulated Power Cable 6   Copper Conductors XLPE Insulated Power Cable 7
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
Copper Conductors XLPE Insulated Power Cable 8   Copper Conductors XLPE Insulated Power Cable 9   Copper Conductors XLPE Insulated Power Cable 10   Copper Conductors XLPE Insulated Power Cable 11
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
Copper Conductors XLPE Insulated Power Cable 12   Copper Conductors XLPE Insulated Power Cable 13   Copper Conductors XLPE Insulated Power Cable 14   Copper Conductors XLPE Insulated Power Cable 15
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
Copper Conductors XLPE Insulated Power Cable 16   Copper Conductors XLPE Insulated Power Cable 17   Copper Conductors XLPE Insulated Power Cable 18   Copper Conductors XLPE Insulated Power Cable 19
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
Copper Conductors XLPE Insulated Power Cable 20   Copper Conductors XLPE Insulated Power Cable 21        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

 

 

  Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Copper Conductors XLPE Insulated Power Cable 22 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  RECOMMENDED ORDERING PARAMETERS

   CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Contact person: Annie Chen

Whatsapp: +86-13670012325
E-mail : annie@cttcable.com
Head office: No.130 Jingsong 3rd road, Lisonglang Community, Gongming Street, Guangming District, Shenzhen, Guangdong, China, 518000

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

INSTALLATION METHOD DETAILS

Copper Conductors XLPE Insulated Power Cable 23 B1 – Electroduct in brickwork (Single-core)
Copper Conductors XLPE Insulated Power Cable 24 B1 – Electroduct in brickwork (multi-core)
Copper Conductors XLPE Insulated Power Cable 25 C – On the wall
Copper Conductors XLPE Insulated Power Cable 26 C – On the ceiling
<img class="src=" photo="" copperconductorcable="" editor="" 20170927191416_90776.png"=""> A1 – Thermally insolated wall (Single-core)
Copper Conductors XLPE Insulated Power Cable 27 A2 – Thermally insolated wall (multi-core)
Copper Conductors XLPE Insulated Power Cable 28 B1 – Apparent electroduct (Single-core)
Copper Conductors XLPE Insulated Power Cable 29 B2 – Apparent electroduct (multi-core)
Copper Conductors XLPE Insulated Power Cable 30 C – Non-perforated tray
Copper Conductors XLPE Insulated Power Cable 31 F – Perforated tray (Single-core)
Copper Conductors XLPE Insulated Power Cable 32 F – Perforated tray (multi-core)
Copper Conductors XLPE Insulated Power Cable 33 F –Suspended (Single-core)
Copper Conductors XLPE Insulated Power Cable 31 F – Perforated tray (Single-core)
Copper Conductors XLPE Insulated Power Cable 32 F – Perforated tray (multi-core)
Copper Conductors XLPE Insulated Power Cable 33 F –Suspended (Single-core)
Copper Conductors XLPE Insulated Power Cable 37 E – Suspended (multi-core)
Copper Conductors XLPE Insulated Power Cable 38 B2 – Construction space
Copper Conductors XLPE Insulated Power Cable 39 B2 – Construction space
Copper Conductors XLPE Insulated Power Cable 40 B1 – Electroduct (Single-core)
Copper Conductors XLPE Insulated Power Cable 41 B2 – Electroduct (Multi-core)
Copper Conductors XLPE Insulated Power Cable 42 B2 – Construction space
Copper Conductors XLPE Insulated Power Cable 43 B2 – Closed raceway embedded in floor (multi-core)
Copper Conductors XLPE Insulated Power Cable 44 B1 – Ventilated raceway embedded in floor
Copper Conductors XLPE Insulated Power Cable 45 C – Embedded in the brickwork
Copper Conductors XLPE Insulated Power Cable 46 D – Buried in additional mechanical protection  